The hard parts · Grease & Drainage

Where the Grease Goes

Every commercial kitchen needs grease waste to reach an interceptor of adequate size, in a location that can actually be pumped out.

Before you sign. We will tell you what the landlord has actually delivered and what it will cost to make it a restaurant.

Pre-lease

We will walk the space before you sign it

Rent clock

Every week of delay is a week of paying for a closed room

Grease

Routing checked before design, not discovered at permit

Licensed

General contractor, licensed in the state of Florida

Sizing and location are both decided by others

The interceptor size is set by the authority based on your fixtures and seats, not by preference. Its location has to be somewhere a service truck can reach. In a tight urban tenancy those two constraints together frequently rule out the obvious spot, and occasionally rule out the space.

Servicing access is the constraint that catches people. An interceptor sized correctly and located where a pump-out truck cannot reach it is not a working interceptor, and relocating one after the floor is finished means cutting the slab in a trading restaurant. The location has to be resolved with the same care as the sizing.

What to establish early

  • Whether an interceptor exists, and its size and condition.
  • The size the authority will require for your operation.
  • A location that a pump-out truck can reach.
  • Floor drains, slopes and the finish the inspector expects.
  • Who is responsible for servicing it, if it is shared.

Floors, slopes and what gets inspected

A commercial kitchen floor has to fall to drains, be cleanable, and stand up to hot water, grease and daily washing down. Coving at the wall junction is part of that, because a square junction cannot be cleaned properly however hard anybody works.

All of it is inspected, and all of it is decided when the slab is poured. Getting the falls wrong is one of the few restaurant construction errors that cannot be corrected without starting the floor again.

How we handle it

  1. 01Confirm interceptor requirements with the authority before design.
  2. 02Verify any existing unit rather than assuming it is adequate.
  3. 03Locate for servicing, not just for the plan.
  4. 04Install drainage, slopes and finishes to what will be inspected.
  5. 05Hand over the servicing requirements to the operator.

Verify an existing interceptor rather than assuming it will do. Inheriting one that is undersized for your operation means installing a new one after the floor is finished, which is the worst possible time to be cutting a slab.

Said plainly

Where we stop

If grease waste cannot reach an interceptor location that can be serviced, the space is not a commercial kitchen. It is a hard constraint and no design resolves it.

FAQ

Common questions

Who decides the interceptor size?
The authority, based on your fixtures and seats. Not preference.
Can we use the existing one?
Only after verifying it is adequate for your operation. Assuming is expensive.
Does location matter?
Yes. It has to be reachable by a pump-out truck.
What if there is nowhere for it?
Then the space is not a commercial kitchen. That is a hard constraint.

Next step

Find out what is actually wrong with it.

An inspection, photographs of what we found, and a written scope. If the honest answer is that it can wait another season, that is the answer you will get.